On 31 January during the investigation of a minor event the staff of Trillo NPP detected a design error in the level instrumentation in the annulus outside the containment sphere (between the sphere and the containment building, 3 out of 4 sumps). This error would have affected the actuation of Residual Heat Removal System (RHR) during a small LOCA, in the recirculation phase. Because of the particular design of Trillo (KWU) this deficiency in 3 sumps would have resulted in inadequate safety function of RHR during a small LOCA.
This deficiency has been present since the start-up of the plant. The error has been corrected and the nuclear safety council is investigating the causes and actions of the Trillo staff. The plant is operating at full power.