CBRN
Radiological/Nuclear
CBRN event in Switzerland on Tue 4th September 1990
4th September 1990
During start up tests after refueling the reactor was made critical (zero power) without pressurized scram accus (violation OL&C). The unavailability lasted 3,5 hours and was detected during shift turnover. No initiator and scram challenge occurred. All other safety systems were available. Remaining shut down function during degradation:
- high reactor pressure replace the scram accus (above 30 bars)
- control rod drive system and boron injection system
Basis for rating: Table III.1 of User's Manual
a) Initiator: Rod ejection unlikely (3)
Safety function: inadequate (D); rating: box D/3=level 1
b) Initiator: Small LOCA possible (3)
Safety function: adequate (C); rating: Box C/2=Level 1.
Contextual analysis
Analysing the event count by highlighting the presence of munition categories over a six-month data period.