Identified CBRN agent

Radiological/Nuclear

CBRN event in United States of America on Tue 26th September 2023

26th September 2023

The source material and subsequent headlines on METIS are collated by our system and taken direct from source. The opinions and views expressed in these source articles and source headlines are not the views and opinions of METIS or its employees.
METIS is not able to substantiate the veracity of sources or check misinformation in real-time. Our analysis is based on currently reported information and may change as new information becomes available.

A radiography trainee received a dose of 0.075 Sv (7.50 rem) to the whole body and 0.258 Sv (25.8 rem) to the extremities due to a disconnected 2.33 TBq (63 Ci) Ir-192 source. This dose was determined through reconstruction of the event and dose calculations. The trainee did not wear his dosimetry badge and he did not turn on his alarming rate meter. He connected the source without supervision and began to take radiography shots of a pipe. After the third shot, he cranked the drive cable without the source back in the camera. He did not perform a survey to make sure the source was back in the camera. He walked up to the pipe and exchanged the film. He moved the end of the guide tube inside the pipe placing his hand approximately four inches from where the source was located. He walked back and cranked the drive cable back to the end of the guide tube and backed away from the cranks during the shot time. He repeated this three more times, and while he was disconnecting the guide tube from the camera to switch to a guide tube with a collimator, he noticed that the indicator on the camera showed that the source was not back in the camera. He checked his personal dosimeter and found it off scale. He reported this to his trainer. The radiation safety officer and an assistant arrived to perform the source retrieval. They inspected the source assembly connector and the drive cable connection, and connected them. They cranked the source back into the camera. The trainee did not have any symptoms of radiation exposure, which was supported by daily pictures of his hands and weekly bloodwork collected for a month. The cause of the incident was failure to properly connect the source assembly to the drive cable followed by a failure to use a survey meter. Another cause was that the trainer did not supervise the trainee. The licensee reported that they have conducted retraining with all radiographers and have suspended the two radiographers in this incident. The licensee has reported that they will increase the frequency of their audits. The dose to the trainee exceeded the U.S. regulatory limit for the annual whole body dose of 0.05 Sv (5 rem). EN56761.

Contextual analysis

Analysing the event count by highlighting the presence of munition categories over a six-month data period.

Enterprise

Understand the complete picture with an Enterprise account.

Learn more

Sign in to view this information

Information sources

Discussion and media of this event has been extracted from all sources.

Sign in to view this information

Enterprise
Verified munitions and items

Below is an item identification verified by our in house experts. Identifications are made from image and video evidence attached to the event.

Sign in to view this information

Enterprise
Country information

Click to view more information about the country and see more information on conflicts occuring in that region.

United States of America (USA)

Discover more

Events using similar munitions or platforms and those that happen within a recent time line and proximity are displayed below.

Enterprise

Understand the complete picture with an Enterprise account.

Learn more

Sign in to view this information